GSL Electronic Special Lightning Surge Withstand Fuse . ferraz-shawmut.com Ferraz Shawmut Home Page
 
 
<< Fuse Selector >>

Fuse Selector

GSL FUSE PRODUCT PAGE
Dimensional Drawing
Part Listing
Time-Current Curves
Specifications
 
CATEGORY - ELECTRONIC
Special Lightning Surge Withstand Fuse
 
SIZE: 5X20gsl
Body Material:GLASS
Acting:LightningWithstand
Axial Leads:No
Printable Version (PDF)
 
DIMENSIONAL DRAWING:
Back on top...
GSL fuse


FUSE SPECS:
Back on top... 
Catalogue
Number
Ampere
Rating,A
Voltage,
Volt
Melting I2t,
A2Sec
Approvals
GSL1/100.1002500.040UL, CSA
GSL1/80.1252500.070UL, CSA
GSL15/1000.1502500.083UL, CSA
GSL16/1000.1602500.089UL, CSA
GSL175/10000.1752500.037UL, CSA
GSL2/100.2002500.140UL, CSA
GSL1/40.2502500.218UL, CSA
GSL3/100.3002500.270UL, CSA
GSL35/1000.3502500.735UL, CSA
GSL4/100.4002500.960UL, CSA
GSL5/100.5002501.375UL, CSA
GSL6/100.6002502.520UL, CSA
GSL63/1000.6302502.778UL, CSA
GSL7/100.7002503.430UL, CSA
GSL3/40.7502503.753UL, CSA
GSL8/100.8002504.480UL, CSA
GSL11.0002507.000UL, CSA
GSL1-1/41.25025012.500UL, CSA
GSL1-1/21.50025018.000UL, CSA
GSL1-6/101.60025020.480UL, CSA
GSL22.00025040.000UL, CSA
GSL2-1/22.50025062.500UL, CSA
GSL33.00025081.000UL, CSA
GSL3-15/1003.15025099.220UL, CSA
GSL3-1/23.500250122.500UL, CSA
GSL44.000250152.000UL, CSA
GSL55.000250212.500UL, CSA
GSL66.000250396.000UL, CSA
GSL6-3/106.300250436.590UL, CSA
GSL77.000250588.000UL, CSA
GSL7-1/27.500250365.620UL, CSA
GSL88.000250414.000UL, CSA
GSL1010.000250650.000N/A
GSL1212.000250999.999N/A
GSL1515.000250999.999N/A
GSL2020.000250999.999N/A

TIME_CURRENT CURVES:
Back on top...
 
GSL fuse
 
TECHNICAL SPECIFICATIONS:
Back on top...
 
Interrupting Ratings
10mA~5A: 10,000 amperes at 125V AC
10mA~1A: 35 amperes at 250V AC
1.25A~3.5A: 100 amperes at 250V AC
3.6A~8A: 200 amperes at 250V AC
 
Operating Temperature:
-55C to +125C
 
Materials:
Glass body / Nickel Plated Brass Caps
 
Lightning Surge Withstand Capability:
Peak current and perk 800V, 10X560 microsec